: The air intake pipe (max length 2m) must be directed away from the vehicle's direction of travel and pointed downward to prevent water ingress. If downward orientation is impossible, a 3mm drainage hole must be drilled at its lowest point.
The 4D-24 is characterized by its high thermal output and efficient fuel consumption. Specification Heating Power 1.5 kW (Min) – 4.0 kW (Max) Fuel Consumption 0.19 L/h (Min) – 0.50 L/h (Max) Air Flow Rate 60 m³/h (Min) – 140 m³/h (Max) Power Consumption 18 W (Min) – 40 W (Max); 100 W during startup Fuel Type Diesel (GOST 305) Installation Requirements Proper installation is critical for safety and longevity. pramotronik 4d 24 instruktsiia
: The unit should be secured on an even surface (unevenness < 1mm) using the provided gasket. Always replace the gasket if the heater is reinstalled. Operating Instructions : The air intake pipe (max length 2m)